banana leaves
4420--Replace RO Water Heat Exchanger
banana leaves
Back

This opportunity is closed, click here to see similar open opportunities.

Title:  

4420--Replace RO Water Heat Exchanger

Agency:  

U.S. Department Of Veterans Affairs

State:  

Ohio

NAICS Code:  

332410

Industry:  

Manufacturing

Solicitation Type:  

Request for Information

Solicitation ID:  

36C25026Q0524

Open Date:  

4/23/2026

Close Date:  

5/1/2026

Last Updated:  

Description:
The Department of Veterans Affairs is seeking information from companies capable of replacing a Reverse Osmosis (RO) water heat exchanger. The heat exchanger has specific requirements, including a shell side and tube side with particular fluid flow rates, temperatures, and pressures. The replacement heat exchanger should have a total heat exchange of 1,049,499.92 Btu/h and an overall heat transfer coefficient of 305.1/262.93 Btu/hr,ft2,°F. The construction of the heat exchanger should include a shell side with a design pressure of 150PSI and a design temperature of 375°F, and a tube side with a design pressure of 125PSIG and a design temperature of 375°F. Interested companies should send an email to the contracting officer with their contact information, socio-economic status, and unique entity identifier (UEI) number. Some key points to consider are: • The heat exchanger should be able to handle a total flow rate of 106.26 GPM on the shell side and 60 GPM on the tube side. • The heat exchanger should be able to operate at a pressure drop of 6.5 / 1.84 PSIG on the shell side and 6.5 / 0.44 PSIG on the tube side. • The heat exchanger should have a surface area of 81.1 ft2 and an excess surface area of 1.32%. • The heat exchanger should be constructed with a tube material of 316 S/S and a diameter of 3/4 in. • The heat exchanger should have a head type/material of CAST SS316 and a tubesheet material of 316 S/S.
Attached Files:

Please visit the bid source via the “Link to Bid Source” button below for documentation.

Contact Information:

Luke A. Turner(Contracting Officer)

[email protected]

(513) 559-3712

Budget Estimate (AI):

$100,000 – $500,000

The budget for this opportunity is difficult to estimate, as the document does not provide a specific budget or cost range. However, based on the complexity of the heat exchanger and the requirements specified, it is likely that the budget will be in the range of $100,000 to $500,000. This estimate is based on the assumption that the heat exchanger will be a custom-built unit with specific materials and design requirements, and that the manufacturing process will require specialized labor and equipment. Factors that may influence the likely payment range include the size and complexity of the heat exchanger, the materials and design requirements, and the manufacturing process and labor costs.

Similar Opportunities powered by Bid Banana AI™

The Bid Lab’s Experts Are Ready To Help You Win RFPs

The Bid Lab is the only RFP consulting firm of its kind, specializing in guiding small and medium-sized businesses through the proposal response process. We have RFP experts ready to help you respond to that perfect opportunity you discover in Bid Banana.

  • Trusted by 100s of small business owners
  • Experience working on 1000s of RFP responses
  • Success stories in virtually every industry you can check out by clicking here.

The Bid Lab Group