This specification governs the full‑containment asbestos‑abatement of pipe insulation and related materials in the swimming‑pool annex of Chancellor Avenue School in Newark, NJ. The work must be performed while the building remains occupied, requiring extensive containment, negative‑pressure enclosures, daily air‑monitoring, and strict waste‑handling procedures. The contractor is responsible for providing all required permits, safety plans, equipment, and post‑abatement clearance testing, and must coordinate closely with the Asbestos Safety Control Monitor (TTI Environmental) and the school’s representatives.
• Scope includes removal of ~270 LF of asbestos‑containing pipe insulation using wet methods and glove‑bag techniques, with disposal to an approved NJ landfill.
• Mandatory daily air‑monitoring, weekly pressure‑differential reports, and strict stop‑action limits (0.5 f/cc for PAPR users, 1.0 f/cc immediate).
• Full documentation required: submittals, daily logs, waste manifests, final clearance certificates, and compliance with NJ and federal asbestos regulations.