Description
The City of Salinaâs 2026 Water Mains Replacement project (ID 26017) calls for the removal and replacement of aging waterâmain infrastructure, associated valve boxes, and related roadway/sidewalk concrete work. The addendum clarifies technical requirements, such as minimum excavation depths, shoring responsibilities, and material standards (ductileâiron pipe pressure classes, Type K copper for short services). Bidders may choose openâcut trenching or directional boring, with two mandatory directional bores under an existing storm sewer. No monetary values or schedule dates are disclosed in this addendum.
⢠Revised general notes require minimum 24âin. box depth, 6 in. of commercialâgrade topsoil, and contractorâprovided OSHAâcompliant shoring.
⢠Specification changes remove pipeâthickness constraints for directionally bored pipe; ductileâiron pipe must meet Pressure Class 350 (⤠12 in.) or Class 250 (⼠16 in.).
⢠Meterâpit dimensions and copper serviceâline requirements are detailed; adapters for subâ1âin meters must be supplied by the contractor.
⢠Both openâcut and directionalâboring methods are permitted; two directional bores are mandatory beneath a storm sewer.
Attached files
The solicitation documents live at the source â open the bid source above to download them.