The government seeks a qualified contractor to replace the existing HVAC system in Room 2821 at Seymour Johnson Air Force Base and perform associated interior architectural restoration. The work includes removal of the old unit, furnishing and installing a new 2‑ton split‑heat‑pump system with a minimum 14 SEER rating, line‑set installation, thermostat programming, testing, balancing, and full interior finish repair (drywall patching, painting) to restore the room to its pre‑project condition. The contractor must provide all labor, materials, equipment, transportation, a $10,000 performance bond, a valid North Carolina HVAC license, and a personnel security roster. The project must be completed within ten business days once on‑site work begins, adhering to base security procedures and standard safety and environmental protocols.
• Provide complete removal, disposal, and installation of a split‑heat‑pump HVAC system (2‑ton, 14 SEER, 10 kW auxiliary heat).
• Perform interior restoration: gypsum wallboard repair, taping, mudding, sanding, and repaint to match existing finishes.
• Deliver testing, balancing, commissioning, and a one‑year workmanship warranty; submit all required documentation before final payment.